Jake Carpenter, a graduate student at Indiana University, presented at the Vanderbilt Seminar Series.
Heavy‑ion irradiation of integrated circuits remains a critical concern for aerospace and high‑energy physics applications, where transient and latch‑up effects can compromise system reliability. This resource examines the single‑event charge‑collection (SCT) and single‑event latch‑up (SEL) response of a custom wide‑band operational amplifier fabricated in the SkyWater S90LN 90 nm process. Understanding radiation‑induced phenomena in such advanced CMOS technologies is essential for designing robust analog front‑ends.
The presentation details the op‑amp architecture, which converts a differential input voltage into a mirrored differential current before producing a single‑ended output. When an energetic ion traverses the circuit, it generates a short‑duration pulse whose width and amplitude depend on the interaction location, producing distinct clusters in pulse‑width versus amplitude space. Four mitigation strategies are implemented: differential charge collection through a common‑centroid transistor layout that cancels transients when both inputs are struck; charge confinement by embedding a deep n‑well and inner p‑well to isolate generated charge; current compensation that sources up to 0.5 mA to counteract charge‑induced voltage excursions; and guard‑ring insertion around the deep‑well/p‑well to suppress latch‑up pathways. Experimental data are acquired at the Lawrence Berkeley National Laboratory 88‑inch cyclotron using a 16 MeV ion cocktail, with measurements of pulse width, peak‑to‑peak voltage, and cross‑section as functions of linear energy transfer (LET) and threshold voltage. The analysis distinguishes genuine micro‑latch events from spurious spikes and employs the I‑REZ statistical method to reject environmental noise identified by random low‑frequency signatures.
With this knowledge, learners can articulate how differential charge collection, charge confinement, and current compensation collectively mitigate radiation effects in op‑amps, and they can compare transient waveforms arising from different ion hit locations. They become capable of interpreting SCT cross‑section data versus LET and threshold voltage, analyzing SEL test results to differentiate micro‑latch occurrences from normal operation, and evaluating experimental procedures to identify and suppress environmental noise in heavy‑ion testing campaigns.